Home > Jcl Error > Jcl Error 032

Jcl Error 032

Contents

A WRITE MACRO WAS ISSUED FOR A RECORD LARGER THAN THE TRACK CAPACITY, AND THE RECORD FORMAT DOES NOT USE THE TRACK OVERFLOW FEATURE. S0E2 - THE ERROR OCCURRED WHILE PROCESSING THE FIRST EXCP OF A VIO DATASET. S202 - 08 - FOR A POST IN A USER KEY AND A WAIT IN A SYSTEM KEY, THE ECB TO BE POSTED DOES NOT MATCH ANY ECB BEING WAITED ON. BAD DAT TABLES OR WRONG STO ADDRESS.

S013 - 64 - AN OPEN MACRO WAS ISSUED FOR A NULL DATASET USING AN ACCESS METHOD OTHER THAN QSAM OR BSAM. IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN THE S16E OPERAND FOR MORE SPECIFIC INFORMATION: H ABEND O(S16E-RC) S16E - 04 - THE INDICATED DEB POINTER IS NOT EITHER NO SYNAD ROUTINE WAS PROVIDED TO HANDLE THE ERROR, OR DCB=EROPT=ABE WAS SPECIFIED OR DEFAULTED.IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN THE S001 OPERAND FOR MORE THE RECORD OR BLOCK LENGTH PLUS THE KEY LENGTH AND REQUIRED OVERHEAD ADD UP TO MORE THAN 32,767 BYTES.

Jcl Error Codes List

S137 - 30 - A LABEL VIOLATED THE PUBLISHED STANDARD FOR THE LABEL, AND THE LABEL VALIDATION EXIT REQUESTED OPEN/EOV TO REJECT THE VOLUME. S233 - 18 - THE 4K SQA BUFFER HAS BEEN REQUESTED (BUFFER=YES) BUT IT IS NOT SERIALIZED (BY SETTING ON THE HIGH ORDER BIT IN CVTSDBF) S233 - 1C - THE S0D3 - A PROGRAM CHECK, INTERRUPTION CODE 19 X'13' (SPECIAL OPERATION ERROR) HAS OCCURRED. EITHER OPEN SPECIFIED UPDAT OR RDBACK, OR THE POINT MACRO FUNCTION WAS SPECIFIED IN MACRF=RP OR WP.

LARGEST BLOCKSIZE FIRST U063 - CHECK SPELLING OF DD STATEMENTS U099 - DATASET NOT FOUND U0000 - DB2 STOPPED UTILID, TABLESPACE U0007/U0240 - VSAM I/O ERROR ON ACKS DATASET(WIDEBAND PROBLEM) U0100 RCT RECOVERY RECORDS THE ERROR INSYS1.LOGREC, PERFORMS RESOURCE CLEAN-UP, REQUESTS A SYS1.DUMP OF THE ADDRESS SPACE AND THEN REQUESTS ADDRESS TERMINATION. S002 - 18 - AN INVALID RECORD WAS ENCOUNTERED ON A PUT OPERATION;THE DATASET USES THE VARIABLE RECORD FORMAT. Jcl Error In Mainframe S306 - 24 - AN AUTHORIZED SERVICE ATTEMPTED TO ACCESS A NON-REENTRANT LOAD MODULE WHICH WAS LOADED FROM AN AUTHORIZED LIBRARY BY AN UNAUTHORIZED CALLER.

S233 - 38 - THE CALLER SPECIFIED THE 4K SQA BUFFER (BUFFER=YES) BUT AN SVC DUMP WAS ALREADY IN PROGRESS. S002 - A4 - UNABLE TO COMPLETE THE READ AGAINST THE PDSE DIRECTORY DUE TO AN ERROR RETURN CODE FROM AN SMS SERVICE USED TO OBTAIN DIRECTORY INFORMATION. S016 - AN ERROR OCCURRED IN SAM SIO/PAGE FIX OR DASD END-OF-BLOCK MODULES BECAUSE OF ONE OF THE FOLLOWING:- THE DASD END-OF-BLOCK MODULES ISSUED AN EXCPVR SVC REQUEST ON BEHALF OF S013 - 24 - AN OPEN WAS ISSUED WITH INPUT, INOUT, RDBACK, OR UPDATE SPECIFIED, BUT THE DCB MACRF DID NOT SPECIFY EXCP, GET, OR READ.

If the error reoccurs, consult your technical support staff IEC015I A34-04 An attempt was made to read an unopened file. Mainframe Abend Codes List Pdf S002 - 08 - AN INVALID RECORD WAS ENCOUNTERED ON A PUT OR WRITE OPERATION. Muchas gracias Andy! S002 - 74 - AN INTERNAL SAM CONTROL BLOCK (PACB) USED FOR STORING PDSE DIRECTORY AND MEMBER INFORMATION IS INCORRECT.

Jcl Error Iefc452i

IEC030I B37-04 There is no space left on the disk volume The data set has reached it's limit of space The disk volume table of contents is full IEC031I D37-04 The S04B - AN INVALID OPERATION CODE WAS PASSED TO A TSO LINKAGE ASSIST ROUTINE (LAR). Jcl Error Codes List S013 - 54 - NO SECONDARY CONTROL UNIT COULD NOT BE FOUND FOR A 1419. Jcl Error Codes List Pdf REPOSITIONING OR UPDATING A SPOOLED DATASET IS NOT PERMITTED.

Subscríbete al Consultorio Cobol por Email Manuales Principiantes COBOL Principiantes PL/I Listados de errores Errores de JCL Errores DB2 Errores de ficheros Errores de sistema Errores IMS Errores CICS Oncodes PL/I S013 - C4- DURING THE CREATION OF A DIRECT DATASET, THE OPEN ROUTINE FOUND THAT THE DCB SPECIFIED READ(R) OR GET(G) IN THE MACRF FIELD. S233 - 28 - AN ASID SPECIFIED IN THE ASID LIST POINTED TO BY THE ASIDLST PARAMETER WAS SYNTACTICALLY INVALID. S20A - 00 - (00 IS THE ONLY POSSIBLE RETURN CODE ASSOCIATED WITH S20A) GETMAIN ERROR. Iec032i E37-04,ifg0554p

S314 - I/O ERROR IN READING DSCB- IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN THE S314 OPERAND FOR MORE SPECIFIC INFORMATION: H ABEND O(S314-RC)POSSIBLE CAUSE:SORTIN JCL GAVE S233 - 10 - IN A USER-SUPPLIED STORAGE RANGE, THE START ADDRESS IS GREATER THAN THE END ADDRESS. S202 - THE POST MACRO INSTRUCTION ENCOUNTERED AN ERROR WHILE PROCESSING AN EVENT CONTROL BLOCK (ECB). S002 - RECORD IS GREATER THAN 32,768 BYTES, EXCEEDS MAXIMUM TRACK LENGTH OR STATED BLOCKSIZE, COULD NOT BE CONTAINED IN ONE EXTENT, OR TOO MANY TRACKS SPECIFIED FOR CYLINDER OVERFLOW.IF THE

S002 - 2C - THE ERROR OCCURRED WHILE OPENING AN ISAM DATASET. Db2 Abend Codes S0A9 - EITHER A HALT NET,CANCEL COMMAND WAS ENTERED OR AN ERROR OCCURRED DURING EXECUTION OF A VTAM MODULE. DFS2802AERRORENUNAREADOINPUT.

S0E4 - THE ERROR OCCURRED WHILE TRYING TO SCRATCH A VIO DATASET.

POSSIBLE DOS VOLUME. S002 - 14 - AN INVALID RECORD WAS ENCOUNTERED ON A PUT OR WRITE OPERATION. S002 - 60 - NON-ZERO KEYLENGTH SPECIFIED FOR OUTPUT PDSE MEMBER. Jcl Return Codes The data set was on a direct access or magnetic tape device.

ACCESS OF A PDSE BY EXCP IS NOT SUPPORTED. S112 - 01 - PARAMETER LIST NOT IN CALLER'S STORAGE. Poe favro pongan el error y el comentario respectivo, gracias 30 de julio de 2011, 6:03 Andy dijo... S30A - 24 - FOR A PRIVATE STORAGE FREEMAIN, THE AREA TO BE FREED IS LARGER THAN WAS SPECIFIED ON THE ORIGINAL GETMAIN, OR THE FREEMAIN START ADDRESS IS NOT VALID.

END ADDRESS OF RANGE NOT GREATER THAN BEGINNING ADDRESS. S0B0 - 08 - INVALID SVA (DOES NOT POINT TO THE BEGINNING OF A SWA PREFIX OR THE SWA PREFIX HAS BEEN DESTROYED). S11A - A PROTECTION CHECK OCCURRED WHEN THE SYSTEM TRIED TO STORE INTO A USER SUPPLIED OS/VS CAMLST WORK AREA. S008 - THE ERROR OCCURRED DURING EXECUTION OF A SYNAD ROUTINE.

EITHER:- WRITE ATTEMPTED TO THE DIRECTORY OF A PDSE.- READ ATTEMPTED TO THE DIRECTORY OF A PDSE AND EITHER THE RECFM WAS NOT F WITH BLKSIZE >= 256ORRECFM WAS NOT U S013 - C8 - THE OPEN SUBSYSTEM EXECUTOR MODULE WAS PASSED AN ERROR RETURN CODE IN REGISTER 15 AFTER ISSUING THE IEFSSREQ MACRO TO CONNECT THE USER'S ACB TO THE SUBSYSTEM.